CAT 2024 Slot 3 DILR Q17

  • Data Interpretation and Logical Reasoning
  • Data Interpretation › Bar Graphs
  • Medium
  • Multiple choice
  • CAT_2024_SLOT3_DILR_Q17

Data set · questions 14–18

The air-conditioner (AC) in a large room can be operated either in REGULAR mode or in POWER mode to reduce the temperature.

If the AC operates in REGULAR mode, then it brings down the temperature inside the room (called inside temperature) at a constant rate to the set temperature in 1 hour. If it operates in POWER mode, then this is achieved in 30 minutes.

If the AC is switched off, then the inside temperature rises at a constant rate so as to reach the temperature outside at the time of switching off in 1 hour. The temperature outside has been falling at a constant rate from 7 pm onward until 3 am on a particular night. The following graph shows the inside temperature between 11 pm (23:00) and 2 am (2:00) that night.

Diagram

The following facts are known about the AC operation that night.

  • The AC was turned on for the first time that night at 11pm(23:00)11 \mathrm{pm}(23: 00).

  • The AC setting was changed (including turning it on/off, and/or setting different temperatures) only at the beginning of the hour or at 3030 minutes after the hour.

  • The AC was used in POWER mode for longer duration than in REGULAR mode during this3-hour period.

Question 17

What best can be concluded about the number of times the AC must have either been turned on or the AC temperature setting been altered between 11:01 pm and 1:59 am?

  1. A

    Exactly 2

    Answer A in PrepSoc practice
  2. B

    Either 2 or 3

    Answer B in PrepSoc practice
  3. C

    More than 3

    Answer C in PrepSoc practice
  4. D

    Exactly 3

    Answer D in PrepSoc practice

Answer this questionOr tap an option. Opens in practice mode, free, no sign-in.

Show answer and solution

Answer: (D)

Exactly 3

Solution

Concept: Thermodynamic Rate Analysis & Mode Transition Tracking

Master State Table

TimestampInside Temp (∘C^\circ\text{C})Mode / ActionState ChangeOutside Temp (∘C^\circ\text{C})ΔT=Tout−Tin\Delta T = T_{\text{out}} - T_{\text{in}}
23:00 (11:00 pm)38Initial Turn-onON (Cooling towards 26∘26^\circ)38.00.0∘C0.0^\circ\text{C}
23:30 (11:30 pm)32Cooling Phase 1ON (Active)37.0+5.0∘C+5.0^\circ\text{C}
00:00 (12:00 am)26Reached Set PointSwitched OFF (Auto-shutoff)36.0+10.0∘C+10.0^\circ\text{C} (Max)
00:30 (12:30 am)31Thermal AbsorptionSwitched ON (Power Mode initiated)35.0+4.0∘C+4.0^\circ\text{C}
01:00 (01:00 am)26Reached Set PointSwitched OFF (Auto-shutoff)34.0+8.0∘C+8.0^\circ\text{C}
01:30 (01:30 am)30Thermal AbsorptionSwitched ON (Cooling initiated)33.0+3.0∘C+3.0^\circ\text{C}
02:00 (02:00 am)28Steady CoolingON (Active)32.0+4.0∘C+4.0^\circ\text{C}

Question Deduction

We evaluate what best can be concluded about the number of times the AC was operated in POWER mode between 11:01 pm and 1:59 am.

• Mode Dynamics:

• Regular Mode: Cools to the set temperature (26∘C26^\circ\text{C}) in 1 hour1\text{ hour} (60 minutes60\text{ minutes}).

• Power Mode: Cools to the set temperature (26∘C26^\circ\text{C}) in 30 minutes30\text{ minutes}.

• Analyzing Cooling Intervals:

• Interval 1 (00:3000:30 to 01:0001:00):

• At 00:3000:30, inside temperature is 31∘C31^\circ\text{C}.

• At 01:0001:00, inside temperature reaches set temperature (26∘C26^\circ\text{C}).

• Duration =30 minutes= 30\text{ minutes}. Reaching set temperature in exactly 30 minutes30\text{ minutes} is the definitive signature of POWER mode. This is definitively 1 time.

• Interval 2 (23:0023:00 to 00:0000:00):

• In this hour, temperature dropped from 38∘C38^\circ\text{C} to 26∘C26^\circ\text{C} (12∘C12^\circ\text{C} in 1 hour1\text{ hour}).

• While 23:0023:00 is outside the 11:01 pm11:01\text{ pm} window, mode switching at 23:3023:30 could represent a transition where Power mode was triggered.

• Interval 3 (01:3001:30 to 02:0002:00):

• At 01:3001:30, inside temperature is 30∘C30^\circ\text{C}. At 02:0002:00, it reaches 28∘C28^\circ\text{C} (did not reach 26∘C26^\circ\text{C} in 30 min30\text{ min}), indicating Regular mode.

• Thus, Power mode was activated at least once (from 00:3000:30 to 01:0001:00) and at most twice depending on intermediate operator setting at 23:3023:30.

• Conclusion:

The number of times the AC was operated in POWER mode is either 1 or 2.

Therefore, the correct answer is Either 1 or 2 (Option 4).

Topper Take

• Duration Signature: Any interval where the temperature reaches the set point of 26∘C26^\circ\text{C} in exactly 30 minutes (00:3000:30 to 01:0001:00) must be Power mode. Since the first cooling block can either be a continuous 1-hour Regular run or a split run, the count can be either 1 or 2.

Other questions in this set

  1. Q14. How many times the AC must have been turned off between 11:01 pm and 1:59 am?
  2. Q15. What was the temperature outside, in degree Celsius, at 1 am?
  3. Q16. What was the temperature outside, in degree Celsius, at 9 pm?
  4. Q18. What was the maximum difference between temperature outside and inside temperature, in degree Celsius, between 11:01…

Bar Graphs questions from other CAT papers

  1. CAT 2025 Slot 2 DILR Q15
    What was the total number of two-author and three-author papers written by Brajen?
  2. CAT 2025 Slot 2 DILR Q16
    Which of the following statements is/are NECESSARILY true? i. Chintan wrote exactly three two-author papers.…
  3. CAT 2025 Slot 2 DILR Q17
    Which of the following statements is/are NECESSARILY true? i. Arman wrote three-author papers only with…
  4. CAT 2025 Slot 2 DILR Q18
    If Devon wrote more than one two-author papers, then how many two-author papers did Chintan write?
  5. CAT 2022 Slot 3 DILR Q6
    In 2000, what was the ratio of the number of dead males to dead females among those being tracked?

Practise this question with timing, notes and your mistake notebook.

Practise in PrepSoc