CAT 2024 Slot 3 DILR Q15
- Data Interpretation and Logical Reasoning
- Data Interpretation › Bar Graphs
- Medium
- Type in the answer (TITA)
- CAT_2024_SLOT3_DILR_Q15
Data set · questions 14–18
The air-conditioner (AC) in a large room can be operated either in REGULAR mode or in POWER mode to reduce the temperature.
If the AC operates in REGULAR mode, then it brings down the temperature inside the room (called inside temperature) at a constant rate to the set temperature in 1 hour. If it operates in POWER mode, then this is achieved in 30 minutes.
If the AC is switched off, then the inside temperature rises at a constant rate so as to reach the temperature outside at the time of switching off in 1 hour. The temperature outside has been falling at a constant rate from 7 pm onward until 3 am on a particular night. The following graph shows the inside temperature between 11 pm (23:00) and 2 am (2:00) that night.
The following facts are known about the AC operation that night.
-
The AC was turned on for the first time that night at .
-
The AC setting was changed (including turning it on/off, and/or setting different temperatures) only at the beginning of the hour or at minutes after the hour.
-
The AC was used in POWER mode for longer duration than in REGULAR mode during this3-hour period.
Question 15
What was the temperature outside, in degree Celsius, at 1 am?
Type-in-the-answer (TITA) question: no options are given; enter the value.
Show answer and solution
Answer:
34
Solution
Concept: Thermodynamic Rate Analysis & Mode Transition Tracking
Master State Table
| Timestamp | Inside Temp () | Mode / Action | State Change | Outside Temp () | |
|---|---|---|---|---|---|
| 23:00 (11:00 pm) | 38 | Initial Turn-on | ON (Cooling towards ) | 38.0 | |
| 23:30 (11:30 pm) | 32 | Cooling Phase 1 | ON (Active) | 37.0 | |
| 00:00 (12:00 am) | 26 | Reached Set Point | Switched OFF (Auto-shutoff) | 36.0 | (Max) |
| 00:30 (12:30 am) | 31 | Thermal Absorption | Switched ON (Power Mode initiated) | 35.0 | |
| 01:00 (01:00 am) | 26 | Reached Set Point | Switched OFF (Auto-shutoff) | 34.0 | |
| 01:30 (01:30 am) | 30 | Thermal Absorption | Switched ON (Cooling initiated) | 33.0 | |
| 02:00 (02:00 am) | 28 | Steady Cooling | ON (Active) | 32.0 |
Question Deduction
We determine the outside ambient temperature at 1:00 am.
• Establishing Outside Temperature Rates:
• The passage specifies that the outside temperature falls at a strictly constant linear rate from to .
• At , the AC is started for the first time. Because the room was previously unconditioned, inside temperature matched outside temperature:
• During the shut-off interval from to :
• The temperature rose from to in .
• The thermal equilibration rule states that when off, the room temperature rises linearly to reach the outside temperature at the time of turn-off in exactly ().
• Therefore, in , the temperature rises by half the differential:
• Deducing the Cooling Rate:
• In the between and , the outside temperature dropped from to :
• Evaluating at 1:00 am (01:00):
Therefore, the temperature outside at 1:00 am was 34 degree Celsius.
Topper Take
• Half-Hour Linear Scaling: The room rose from to in (a increase). Reaching full outside temperature in means total increase is , fixing outside temp at as .
Other questions in this set
- Q14. How many times the AC must have been turned off between 11:01 pm and 1:59 am?
- Q16. What was the temperature outside, in degree Celsius, at 9 pm?
- Q17. What best can be concluded about the number of times the AC must have either been turned on or the AC temperature…
- Q18. What was the maximum difference between temperature outside and inside temperature, in degree Celsius, between 11:01…
Bar Graphs questions from other CAT papers
- CAT 2025 Slot 2 DILR Q15
- CAT 2025 Slot 2 DILR Q16
- CAT 2025 Slot 2 DILR Q17
- CAT 2025 Slot 2 DILR Q18
- CAT 2022 Slot 3 DILR Q6
Practise this question with timing, notes and your mistake notebook.
Practise in PrepSoc